7. PCB A0224028 REV:1.1
一. Software specification
1.operating system Windows 98/2000/xp
2. Language per operating system English US, English UK, Japanese
二. 可靠度測試 reliability test
1.環境測試 environmental
項目item
|
條件condition
|
規格 specification
|
(1) 高溫高濕測試
High temperature operation test
|
1.temperature: 5℃ 2.Humidity: 90%+/-2%RH 3.test time period: 24hours at temperature and humidity.
|
All HUB features must function at temperature and humidity after time period
|
(2) 低溫測試
cold temperature operation test
|
1.temperature: 0℃ 2.test time period: 24hours at temperature
|
All HUB features must function at temperature and humidity after time period
|
(3) 儲存循環
Storage cycle
|
a) Temp. : 1). High: 65℃ upon reaching high temperature, ramp humidity to 90%RH 2). Low: -40℃ b). Test time period: 40hours,temperature (high &low).
|
After test, the product function is normal
|
2.機械性能測試 Mechanical
Drop
|
Height: 75cm; surface: 2.5cm iron; Orientation: 3times each of top, bottom, left, right, front and back.
|
HUB must operate after test
|
Vibration
|
force: 2.8g max, freq. range:10-300 Hz; freq. scan:0.5oct/min;duration:1hr direction X, Y, and Z axis
|
HUB must operate after test
|
Cable Bend Test
|
Oriencation : Bend cable 3000 times
Range:120degrees
Temperature:25oC
|
|
Cable Pull Test
|
Force :Pull cable with 3KG
Test Time Period: 1 minute
Temperature:25oC
|
|
3. 電氣性能測試Electrical
Power On / Off Test
|
1.function ok sample: 6Pcs 2.standard input voltage: 5.0v 3.On for 20sec;Off for 10sec; cycle: 1250times at 50degree C / 50%RH.
|
HUB must operate after test
|
M.T.B.F TEST
|
1.Environment: 25Degree C / 50%RH. 2.Time:1000Hrs / input Voltage: 5.0v 3.Provide calculated M.T.B.F using 95% confidence interval.
|
All HUB features must function at temperature for time period.
|
|